5 SIMPLE STATEMENTS ABOUT DP50RB EXPLAINED

5 Simple Statements About Dp50rb Explained

5 Simple Statements About Dp50rb Explained

Blog Article

The user is just not allowed to open up the handles and panel from the method, neither NOTE: unit disassemble is permitted. To ensure the process effectiveness and protection, only Mindray engineers or engineers approved by Mindray can accomplish servicing.

.. Site 161 The indicator on the printer Errors take place once the adapter turns orange, plus the printing printer adapter runs. Disconnect and link the fails. energy adapter, electricity to the printer adapter yet again, and confirm whether or not the printing is normal just after 1 moment. Webpage 163: Electrical Protection Inspection

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

The chapter provides the method to validate most important purpose and functionality of product or service. This can be only used for reference, not preventive execution. Functionality checking and screening of this aspect shall be carried out by Mindray support engineers along with the person jointly. Web site sixty six: Basic Examination

Will not use any cables apart from the cables offered with the product by Mindray. three. Use the cable provided with this system to attach the printer. Other cables might bring about electric powered shock. Web site 15: Mechanical Basic safety

General performance Take a look at 5.five.1 Check Method Resolution Detection depth Geometric Place Precision Blackout area exam Report the exam photos 5.five.two Take a look at Articles The image made use of here is only for reference, follow the picture outcome in the actual NOTE: scenario. Necessities: Screen: established the contrast and brightness for the medical application price (or the default status) Procedure atmosphere: dark area, simulating the clinical application ecosystem. Website page seventy six In issue the transverse resolution screening targets are horizontally shown, history the minimal length of two targets which might be clearly recognized. Repeat the Procedure earlier mentioned for the transverse resolution tests targets at other depths. As revealed in determine underneath. Axial resolution ... Site seventy seven When using the convex probe, continue to keep the transverse resolution screening targets to NOTE: be displayed near the midline. When using a linear probe with steer operate, don't turn on the steer purpose when perform the transverse resolution examination. Zoom within the area wherever the targets located if necessary. The diameter of your goal stage at a specific depth is equivalent for the transverse resolution on the depth. Web page seventy eight 5.

five.2.three Geometric positioning precision Longitudinal geometric positioning precision  Exam Stage: Do adjustments as the best way in tests the utmost depth. Record the distance by 20mm Every single section to the longitudinal targets line utilizing the measurement caliper; Find the worth with the best error (to 20mm), estimate the precision utilizing the system down below The measurement caliper should be positioned in the upper edge of the target, NOTE:... Page 79 Transverse geometric positioning precision  Check Move: Include the scan area in the phantom with water or pair gel, gently Get in touch with the probe Together with the scan surface Regulate the depth, creating the transverse targets to become exhibited from the impression. Change the focus position to get posited beside the transverse targets (the conventional is not very clear) Alter parameters like obtain, TGC, generating Each individual transverse targets to generally be Plainly shown. Website page eighty five.5.2.4 Blackout Location Take a look at Step: Protect the scan surface area from the phantom with h2o or pair gel, gently Call the probe with the scan surface area Regulate the depth at a lessen value, and established the main target at the closest location to the scan floor. Minimize the worth of parameters like AP, Acquire until finally the qualifications sounds just could be seen. Web page 81: Software program Enhance And Maintenance

Highest four periods tasking for one particular transmitted beam, leading to exceptional time resolution and higher frame rate.

Aid 4D probe; realize the probe by way of the ID code; change the 4D travel sign via the  electrical relay to generate the 4D probe perform normally. four.two.two Primary board The most crucial board could be divided into two elements: entrance-conclusion of the key board and back-conclusion of the key board.

Return to the technique preset interface. The choice position changes into Uninstalled. The uninstalling perform is distinctive to inner consumers.

Get an entire and extended check out of your anatomical construction as a result of panoramic imaging coupled with velocity sign and forward/backward scan potential building scanning easier, smoother Dp50rb login and a lot more controllable.

A wise new condition, enhanced mobility and practical operation make DP-fifty well matched for all medical configurations.

Your Instrument for deeper biopsy: permitting changes towards the scan line to gain superior visibility from the needle, nerves and modest vessels, guaranteeing the continuity of all facts.

Report this page